Computer room introduction

The Warring States Policy provides Hong Kong, Singapore, Philippines, Thailand, Indonesia, India, Malaysia, Vietnam, Japan, South Korea, the United States, Taiwan,
The top international telecom rooms in Canada, London, Paris and Amsterdam will give your website the most solid competitive advantage!

Security Control Service

Provide firewall,
Security control services such as data backup.

Good bandwidth quality

Owns Chunghwa Telecom computer room (100% Hinet line)
Backup network bandwidth, provide enterprise users with quick access and diversify risks.

Professional network data center room

Warring States Policy currently places the host in the Hinet computer room to provide system equipment for stable network maintenance.

low cost

Enterprises do not need to rent software and hardware equipment, and do not need to hire MIS personnel to maintain website software and hardware equipment on their own, which can save personnel costs, and enterprise users greatly reduce website construction costs.

The characteristics of professional IDC services are as follows

Tailor-made high-quality infrastructure

  • Professional computer room construction and management services
  • Professional management team for customized facilities
  • Double loop and N+1 design to achieve 99.999-XNUMX XNUMX% stability
  • 20A plug-in switch per loop, continuous upgrade
  • Completely separated power and telecommunication trunking
  • Class F design of high-quality busbar
  • Ground resistance <0.5 Ω
  • Double circuit power, hydraulic and telecommunications pipeline

99.999% power and backup system

  • Double circuit Taipower Electric, 11.4KV high voltage system.
  • Double-circuit high-voltage transformer 5000KVA*2.
  • Double circuit & N+1 uninterruptible power system (600KVA).
  • 20 minutes of battery power backup.
  • 1500KW, N+1 generator can run continuously for 24 hours.
  • 36-hour fuel reserve tank.
  • K-13 dual-circuit 1000KVA isolation transformer.

N+2, dual circuit air conditioning system

  • Water-cooled independent microcomputer constant temperature and humidity air conditioner
  • Dual circuit design
  • N+1 air conditioning water tower
  • N+2 air-conditioning host
  • 7-day water storage tower
  • With liquid leakage detection function
  • The best working environment (The temperature of the air conditioner is maintained at 22°C +/- 1°C, and the humidity is maintained at 50+/- 5%.)

Fire early warning detection and suppression system

  • Concept: Prevention is more important than containment afterwards.
  • Connect the building's environmental control system with the early smoke detection system.
  • Use FM200 as a fire fighting tool.
  • Multiple detections to prevent false warnings and actions.
  • Use CO2 and dry powder fire extinguishers in the basement.
  • Prepare emergency operation procedures to prevent accidents.

XNUMX/XNUMX maintenance center

  • 24-hour building police inspections and lane control.
  • Use fingerprint reader and card reader to do access control.
  • Use a 360° surveillance camera system and a motion detection system to monitor at any time.
  • Network, security and building environment management all year round.
  • Electromechanical maintenance personnel are on standby XNUMX/XNUMX